Thermal Performance Measurements of Sealed Insulating Glass Units with Low-E Coatings Using the MoWitt Field Test Facility
Publication Type
Conference Paper
Date Published
01/1987
Authors
Abstract
Using data obtained in a mobile field-test facility, measured performance of clearsand low-emissivity double-glazing units is presented for south-facing and north-facingsorientations. The changes in U-value and shading coefficient resultingsfrom addition of the low-E coating are found to agree with theoretical expectationssfor the cold spring test conditions. Accurate nighttime U-values weresderived from the data and found to agree with calculations. Expected correlationsbetween U-value and wind speed was not observed in the data; a plausible experimentalsreason for this is advanced.
Journal
ASHRAE Winter Meeting, Symposium on Fenestration Performance
Year of Publication
1987
Organization
Building Technologies Department, Building Technology and Urban Systems Division, Windows and Envelope Materials