An Energy Efficient Window System, Final Report
Publication Type
Report
Author
Abstract
The purpose of this program was development of commercial production plans for a practical and cost effective energy conserving retrofit system for windows based on Sunteks prototype Superpane retrofit window. The original Superpane configuration consisted of a transparent insulation know as Heat Mirror to reduce radiative heat loss, a thermally sensitive optical shutter known as Cloud-gel to reduce summer heat gain, and a contained air space to reduce convection, all related to the prime window by an appropriate edge detail.
Year of Publication
1977